Search results for "fluid responsiveness"
showing 3 items of 3 documents
Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.
2009
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …
Pulse wave transit time measurements of cardiac output in septic shock patients: a comparison of the estimated continuous cardiac output system with …
2015
Pôle EAMERSCT3Hors Enjeu; Background We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion. Methods Mechanically ventilated patients admitted to the ICU, aged > 18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) …
Arterial Load and Norepinephrine Are Associated With the Response of the Cardiovascular System to Fluid Expansion
2021
BackgroundFluid responsiveness has been extensively studied by using the preload prism. The arterial load might be a factor modulating the fluid responsiveness. The norepinephrine (NE) administration increases the arterial load and modifies the vascular properties. The objective of the present study was to determine the relationship between fluid responsiveness, preload, arterial load, and NE use. We hypothesized that as a preload/arterial load, NE use may affect fluid responsiveness.MethodsThe retrospective multicentered analysis of the pooled data from 446 patients monitored using the transpulmonary thermodilution before and after fluid expansion (FE) was performed. FE was standardized be…